Manual·Chapter 8 of 15

Remote control followspots

This chapter is for productions that use a remote control followspot system: RoboSpot, GroundControl, Follow-Me, Macula or any other. On these systems the fixture is in the rig and the operator works from a base station, so control of intensity, and often of colour, size, frost and time, can sit with the operator or with the lighting console. The chapter covers the settings that record who controls what, and how each layout, the calling script and the PDFs present it.

The application does not communicate with the remote followspot system. It records control, which is common to every system, so no setting is specific to a manufacturer. All of the settings are in Settings, Spots.

Turning the feature on

Settings, Spots, Remote Control Followspots contains the tick box This show uses remote control followspots. Every setting and marking described in this chapter is hidden until it is ticked. A production with conventional followspots only leaves it clear, and its plot is unchanged.

Who normally controls intensity

With the feature on, Intensity is normally controlled by sets the default for the production:

  • The operator (console overrides flagged CONSOLE). The operator runs the intensity. The console takes it on particular cues.
  • The console (operator cues flagged OPERATOR). The console runs the intensity. The operator takes it on particular cues.

Every layout, the calling script and the PDFs read this one setting, so they cannot disagree about who controls the intensity on a cue.

Marking a cue that differs from the default

On the Master plot, each spot's action and intensity cell carries an intensity control chip reading OPERATOR or CONSOLE. The chip is dimmed on a cue that follows the production default. Select the chip and choose Operator runs intensity or Console runs intensity to set that cue. Choosing the production default again clears the setting, and the cue follows the default once more.

A cue that differs from the default is flagged:

  • On the Master plot, the chip is shown in full colour.
  • On the operator layouts, a CONSOLE or OPERATOR flag appears on the cue. Cues that follow the default carry no flag, so the flag marks only the exception.
  • In the calling script, the line adds "desk takes the level" or "operator takes the level", highlighted in the line.
  • On the PDFs, the flag is printed on the cue.

The Intensity fader down reminder

When the operator normally runs intensity and a CONSOLE cue takes the beam to zero, the operator's own fader is still up, and the followspot would return to that level the moment the console hands intensity back. An amber Intensity fader down bar under the notes, the same shape as a colour change prompt, reminds the operator to pull the fader down ready for the next pickup. It appears on the Master plot and the operator layouts, prints on the PDFs, and is spoken in the calling script after "desk takes the level".

The reminder appears only when all three conditions are met: the production default is the operator, the cue is set to CONSOLE, and the cue ends at zero. The tick box Show an Intensity fader down reminder when the console takes a spot to zero, in the Remote Control Followspots card, turns it off.

Console sets the intensity limit

On some productions the console sets the maximum intensity of a remote followspot and the operator always fades to full. This is often called ceiling mode. The levels written in the plot then describe what the console does, and the operator needs to know only whether the followspot is lit.

Each spot's own block in Settings, Spots contains the tick box Console sets this spot's intensity limit (operator always fades to full). When it is ticked for a spot:

  • That spot's operator layouts read ON and OFF in place of levels. A level above zero reads ON. A level of zero reads OFF.
  • A value with two movements keeps its form. 50/0 reads ON/OFF, and 0/90 reads OFF/ON.
  • The calling script does not speak levels for that spot.
  • That spot's List and Tracking PDFs, and the overlay text for VOR and KoalaCue, read ON and OFF.
  • The Master plot keeps the levels as written. No data is changed, and clearing the tick box restores the levels on every layout.

Parameters the console controls

On a remote control rig the console frequently runs the colour, the beam size, the frost or the timing of a followspot. The operator has no control of these and does not need to read them.

Each spot's own block in Settings, Spots lists The console controls these, so hide them from Spot N's operator, with four tick boxes: Colour frame, Size, Frost / hard edge and Time. A ticked parameter is removed from:

  • that spot's operator layouts;
  • that spot's instructions in the calling script;
  • the overlay text for VOR and KoalaCue;
  • that spot's List and Tracking PDFs.

The Master plot always shows every parameter, so the plot remains the complete record of what the console does. This setting is separate from the intensity limit setting, and either can be used without the other.

Conventional and remote followspots in one plot

The production default and the cue markings apply to the whole production. The intensity limit and the console-controlled parameters are set for each spot. A production can therefore run conventional and remote followspots in the same plot: a conventional followspot's operator continues to see levels, frames and sizes, while a remote followspot's operator sees only what that operator controls.

Summary of where each setting appears

OutputA cue that differs from the defaultA spot with the intensity limit setParameters the console controls
Master plotCONSOLE or OPERATOR chip in full colourLevels as writtenShown
Operator layoutsCONSOLE or OPERATOR flagON and OFFHidden
Calling script"desk takes the level" or "operator takes the level"Levels not spokenNot spoken
List and Tracking PDFsFlag printedON and OFFHidden
Master plot PDFFlag printedLevels as writtenShown
VOR and KoalaCue overlay textCONSOLE or OPERATOR in the textON and OFFHidden

Back to the contents